To send data to the Events Service, you must first connect to the Events Service. AppDynamics uses API keys and connection URLs to establish connections between components. 

You can configure these connection settings on the Controller Settings page of the Admin Console (see Access the Administration Console). The following sections describe the required connection settings for Database Visibility, Application Analytics, and End User Monitoring. 

Database Visibility and Application Analytics Connection Settings

The Database Visibility module stores some of its data (such as wait state information and query information) in the Events Service. If you have both Application Analytics and Database Visibility installed, we recommend that they share an Events Service instance or cluster instance. 

To connect Database Visibility and Application Analytics to the Events Service, open the Admin Console Controller Settings and set values for the following properties:

  • Set appdynamics.on.premise.event.service.key to the corresponding key in the properties file for Database Visibility.
  • Set appdynamics.on.premise.event.service.url to the Events Service endpoint URL.
  • Set appdynamics.non.eum.events.use.on.premise.event.service to true.

End User Monitoring Connection Settings

Open Admin Console > Controller Settings and verify if the eum.es.host to the Events Service endpoint URL is set appropriately. To connect both EUM to the Events Service, set values for the following properties in the file, <EUM_HOME>/eum-processor/bin/eum.properties:

  1. In the file <EUM_HOME>/eum-processor/bin/eum.properties, set values for the properties as follows: 

    Sample
    analytics.enabled=true
    analytics.serverScheme=http
    analytics.serverHost=events.service.hostname
    analytics.port=9080
    analytics.accountAccessKey=1a59d1ac-4c35-4df1-9c5d-5fc191003441
  2. Open the Admin Console Controller Settings and set eum.es.host to the Events Service endpoint URL.

The value of appdynamics.es.eum.key will automatically be set to the property analytics.accountAccessKey of the file <EUM_HOME>/eum-processor/bin/eum.properties

Proxy Connection Settings

If you are connecting Database Visibility or Application Analytics through a proxy, you must set values for the following properties:

  • appdynamics.on.premise.event.service.proxy.host
  • appdynamics.on.premise.event.service.proxy.port
  • appdynamics.on.premise.event.service.proxy.user
  • appdynamics.on.premise.event.service.proxy.password.file
  • appdynamics.on.premise.event.service.proxy.use.ssl

If you are connecting EUM through a proxy, you must set values for the following properties:

  • appdynamics.controller.http.proxyHost
  • appdynamics.controller.http.proxyPort
  • appdynamics.controller.http.proxyUser
  • appdynamics.controller.http.proxyPasswordFile